ADAPTIVE MEDICAL SYSTEMS
|
DICOM Free Software ( DICOM Free Viewer ) - "AS_GSV0.FreeVersion"
AS_GSV0.FreeVersion software, represents 2D CAD for works with High Resolution Primary DICOM Images, consisting of following Software Modules:
1. Real Time Stream 2D Processing and Visualization DICOM Images,
2. Real Time Zoned 2D Processing and Visualization DICOM Images,
3. Graphical Patients Navigator PATNAV,
4. Graphical Patients DataBase GDB (In FreeVersion it is included only "Demo GDB")!,
5. PrePrinted Processing, Viewing and Multiple-Frames Print.
The system consists of Modules and supports one, two and more monitors configurations with the each monitor's resolution not less 1600*1200*32b !!
DICOM Free Software - "AS_GSV0.FreeVersion" software realization is accessible to downloading:
- (240MB), includes:
- AS_GSV0.FreeVersion System Files 21MB it is required (10MB in ZIP format).
- AS_GSV0.FreeVersion 4 Manual PDF Files (key F1) the place on a HDD 26MB is required (26MB in ZIP format).
- AS_GSV0.FreeVersion 12 Demo Series the place on a RTBank's 210MB is required (96MB in ZIP format).
- AS_GSV0.FreeVersion DICOM Demo Files of 6 Patient's on a GDB 405MB is required (108MB in ZIP format).
Unpack ZIP archive in a temporsry folder and follow further to instructions in a file "install.txt".
DICOM Free Software - "AS_GSV0.FreeViewerMin" software realization is accessible to downloading:
- (35MB), no includes:
- AS_GSV0.FreeVersion DICOM Demo Files and Demo Series of Patient's on a GDB.
Unpack ZIP archive in a temporsry folder and follow further to instructions in a file "install.txt".
Features SOFTWARE "AS_GSV0.FreeVersion"
- AS_GSV0.FreeVersion is freely distributed version of AS_GSV v.2.5 full software system.
AS_GSV0.FreeVersion has zero cost of purchase and unlimited validity.
AS_GSV0.FreeVersion is the software for professional Streamed, Zoned and PrePrinted Processing workstations of Real Time 2D Processing and Visualization DICOM Medical Images.
AS_GSV0.FreeVersion is submitted in a way such as it is, and intended for examination, demonstration of capabilities, users training and for testing compatibility with DICOM used files.
- AS_GSV0.FreeVersion is full-function AS_GSV full version on processing and visualization of DICOM images which are accessible to the user in complete volume. There are some functional restrictions:
- Only for Demo series results preservation options of Scenarios for images processing are accessible;
- Only for Demo series results preservation options of images processing on HDD are accessible;
- Only for Demo series the last phase of direct printing function on a printer is accessible;
- The work with the Graphical Database (GDB is included only "Demo GDB" in the AS_GSV0.FreeVersion) and the options connected to it for program installation simplification of process and attention fixation of the user to the training process of DICOM images' processing and visualization technologies is inaccessible;
- The work with DICOM files in the JPEG2000 images' format is inaccessible (it is accessible in AS_GSV version).
- AS_GSV0.FreeVersion expands up to AS_GSV full-function version for one-user (local) without GDB with an opportunity of transition to item 4 - item 5.
After payment by the user for the chosen set of program Modules availability of AS_GSV full-function options is provided by Dallas Semiconductor firm's electronic iButton keys, supplied with the software
(2D_Price).
- AS_GSV0.FreeVersion expands up to one-user (local Client-Server) AS_GSV version with GDB on InterBase 6.0 Free Borland Corp. and with an opportunity of transition to item 5.
- AS_GSV0.FreeVersion expands up to multi-user (Client-Server) AS_GSV version with GDB on InterBase 6.0 Free Borland Corp. It is integrated in PACS system with DICOM servers or in an original clinical network on multi-machine DICOM files Archive based on " Patients Data House" technology.
|
The resources necessary for AS_GSV0.FreeVersion. Urgent Recommendations.
- Operation System: Windows 2000 & SP3; Windows XP Pro & SP1; Windows 2003; Windows.NET ...
Special deliveries: Microsoft Windows NT 4.0 & SP6 & DirectX 5.0.
- Free space on HDD not less 1.5GB for temporary files and the processed series or frames.
For AS_GSV0.FreeVersion it is desirable to allocate separate logic or physical NTFS a disk in the size 50GB and more:
- Temporary bank WBuffers for disassembly DICOM files which have been not imported in GDB, should be not less 1GB;
- Temporary banks RTBanks-01...n can occupy up to 20-50GB HDD.
Installation of all Software Modules & Demo series is made in one section or a folder, chosen the user for accommodation AS_GSV0:
- AS_GSV0.FreeVersion System Files 20MB it is required.
- AS_GSV0.FreeVersion 12 Demo Series the place on a RTBank 210MB is required.
- AS_GSV0.FreeVersion DICOM Demo Files of 6 Patient's on a GDB 405MB is required.
- AS_GSV0.FreeVersion Manual Files in PDF format (it is started by key F1) the place on a HDD 26MB is required.
- On 1GB DICOM Storages it is necessary less 0.5 MB GDB database for DICOM patients data and processing Scenarios, and (3-5)MB database for Representative Frames compresed of DICOM series (for calculations).
- !!Necessarily!! One or tho PCI-E / AGP / 64b PCI-X / PCI Matrox 2D adapters G-Series (G450 / G550) ( DualHead 16/32MB and more ) or P-Series (P650 / P750 / Parhelia / Parhelia HR ...) and a conclusion to each monitor with the resolution from 1600*1200*32b 75Hz and more!
- !!Necessarily!! One or tho 19"-21" HR resolution monitors from 1600*1200*75Hz and more up to 2.5k*2.0k*60Hz.
- Tho (or one) CPU Athlon64/Opteron 250 and more or tho (or one) CPU Intel P4/3200 and more
(up to tho dual core CPU for Real Time Processing DICOM images).
- 1GB or 2GB DDR400 RAM (up to 4GB and more) for dual channel mode mainboard chipset controllers.
- Adobe Acrobat Reader 4.0 (and more version) and Acrobat Distiller for printing in PDF files.
|
|